Sources are available as 1” disc or as thin plastic laminate.

Disc SourcesLaminate Source

 

 

Ba-133S

 

1 µCi      (gamma)

Cd-109S

1 µCi      (gamma)

Co-57S

1 µCi      (gamma)

Co-60S

1 µCi      (gamma)

Cs-137S.25

0.25 µCi  (beta and gamma)

Cs-137S.5

0.5 µCi  (beta and gamma)

Cs-137S               

1 µCi      (beta and gamma)

Cs-137S5               

5 µCi      (beta and gamma)

Eu-152S

 1 µCi     (gamma)

Mn-54S

1 µCi      (gamma)

Na-22S

1 µCi      (gamma)

Po-210S

0.1 µCi  (alpha)

Sr-90S

0.1 µCi  (alpha)

Tl-204S

1 µCi      (beta – for backscatter)

Zn-65S

1 µCi      (gamma)

C-14LDS10

10 µCi    (beta)

Fe-55LDS-10

100 µCi (beta, x-ray)

 

RSS-2

Resolving Time set consisting of 2 each T-201 half discs plus a blank for determing GM deadtime.

 

RSS-2 Source

 

RSS-3

Set of three solid sources – Po-210S alpha, 
Sr-90S beta,  Co-60S gamma

RSS-3 Source

 

 

RSS-4

Set of four gamma sources,  Co-57, Cs-137,
Co-60 and “unknown”

 

RSS-5

Set of five solid sources – Po-210S alpha,  Sr-90S beta,  Co-60S gamma, Cs-137S5 gamma

 

RSS-5 Source

 

RSS-8

Set of eight gamma sources for scintillation spectrometry. Includes BA-133S, Cd-109S, Co-57S, Co-60S, Cs-137S, Mn-45S, Na-22S and the mixed source Cs/ZnS as an "unknown" for student identification.

 RSS-8 Sources

 

 

 

LSDISK01LSDisk01

For single gamma sources of >5 uCi, the LSD01 Lead Shield simplifies shipping problems and offers ultra-safe storage of sources.

 

 

 

LSDISK50LSDisk50

With a wall thickness of 0.5'', this container is suitable for higher activity gamma sources. Holds up to 20 discs. Outside Dimensions: h= 3.6 x 2.25", Interior Dimensions: h= 2.65 X 1.25", 0.5" thick, approximately 4.6 lbs weight, painted exterior.

            

 

NEEDLE SOURCESNeedle Source

Needle sources are used to generate a point source of radiation inside cloud chambers for demonstrating alpha and beta radiation tracks. Three different types of isotopes are offered, a pure alpha emitter, a pure beta emitter and a combined alpha /beta emitter.

NS-Po-210

0.01 µCi      (alpha emitter)

NS-Sr-90

0.01 µCi      (beta emitter)

NS-Pb-10

0.01 µCi      (alpha/beta emitter)

 

 

TUBE AND ROD SOURCESTube Sources

Exempt quantity gamma sources encapsulated in standard size test tubes or rods for use with well type radiation detectors. These sources are uncalibrated and of nominal activity. The isotope is deposited as a point source in the bottom of the tube and is then sealed with epoxy. Size must be stipulated: Tube Source 13x100mm, Rods 0.375” or 0.5”

Ba-133TS

0.1 µCi   

Co-60TS

0.1 µCi   

Cs-137TS

0.1 µCi 

Cs-137TS

1.0 µCi   

Ba/CsTS

0.1 µCi   (Mixture of Ba-133 and Cs-137)

Cs/CoTS

0.1 µCi   (Mixture of Cs-137 and Co-60)

 

 

Isotope GeneratorIsotope Generator

This Cs-137/Ba-137m Isotope Generator is used to conduct experiment in schools and universities to demonstrate the properties of radioactive decay. Based on the original Union Carbide patented design, it offers exceptional performance combined with ease of use and safe operation.

ISO

10 µCi    Cs-137/Ba-137m Isotope Generator with 250ml of eluting solution

ELSN

Replacement Eluting Solution, 250ml

CC100

1” dia aluminum planchet, packet of 100