Geiger-Probes

HP-265 Pancake GM Probe

The most popular probe for general survey, radiation safety, contamination checks and emergency response.  Uses a pancake style (wide window, better sensitivity) halogen quenched Geiger-Mueller detector.  Thin mica window allows detection of alpha, beta and gamma radiation.  Available with standard 30 bend or optional 10 bend.

·         Thin Window (1.6 mg/cm²)

·         Available with standard bend or slight bend for ease of use

·         Designed for easy replacement of GM tube

·         Protective Copper/Bronze Screen- 72% Open Area

HP-265 Spec Sheet.pdf

 

GP-200 End Window GM Probe

A popular probe for general survey and radiation safety.  Uses an end window halogen quenched Geiger-Mueller detector.  Thin mica window allows detection of alpha, beta and gamma radiation.  Helpful if probe needs to reach into places to big for the standard pancake probe.

·         Thin Window (1.6 mg/cm²)

·         Compact Design for small areas

·         Designed for easy replacement of GM tube

·         Protective Copper/Bronze Screen- 90% Open Area

GP-200 Spec Sheet

 

GP-1001 GM Probe

Excellent small energy-compensated GM probe for general gamma monitoring.  Good energy response from 40keV to 1.5 MeV. Rugged anodized aluminum housing with BNC coaxial connector for quick field replacement.

·         Range up to 200 mR/Hour

·         Standard BNC Connector works with many survey meters

·         Designed for easy replacement of GM tube

·         Energy compensated

GP-1001 Spec Sheet

 

GP-1002 GM Probe

Excellent small energy-compensated GM probe for higher range gamma monitoring.  Good energy response from 40keV to 2 MeV. Rugged anodized aluminum housing with BNC coaxial connector for quick field replacement.

·         Range up to 2000 mR/Hour

·         Standard BNC Connector works with many survey meters

·         Designed for easy replacement of GM tube

·         Energy compensated

GP-1002 Spec Sheet

 

GP-1003 GM Probe

Excellent small energy-compensated GM probe for very high range monitoring.  Good energy response from 40keV to 2 MeV. Rugged anodized aluminum housing with BNC coaxial connector for quick field replacement.

·         Range up to 10,000 mR/Hour

·         Standard BNC Connector works with many survey meters

·         Designed for easy replacement of GM tube

·         Energy compensated

GP-1003 Spec Sheet

 

GP-1010 GM Probe

The original “Hot Dog” probe.  Very good gamma/beta detector. Good energy response from 60 keV to 2 MeV. Rugged chrome plated brass housing with BNC coaxial connector for easy field replacement.  Built-in rotating beta shield.

·         Extremely Durable

·         Rotating Beta Shield

·         InDesigned for easy replacement of GM tube

·         Standard BNC Connector works with many survey meters

GP-1010 Spec Sheet

 

Scintillation Probes

GLE-1 Low Energy Scintillator

An excellent detector for Iodine-125 and other low energy emitters.  Also good for X-rays as well as beta emitters above 500 KeV.  Encased in a special durable housing. 

·         Thin crystal (2mm) for low energy

·         Durable housing

·         Great for Iodine-125 and X-ray

·         Works with all Johnson meters

GLE-1 Spec Sheet

MRSP-1 Plastic Scintillator

Excellent tissue equivalent micro-R gamma detector. Good energy response from 15 keV to 2 MeV. Includes beta window.  Mounted in shock-resistant housing.

·         Tissue Equivalent Plastic Detector

·         Durable Shock-resistant Housing

·         Wide Energy Range uR Probe

·         Works with all Johnson meters

MRSP-1 Spec Sheet

 

GSP-1 1 X 1 Sodium Iodide Scintillator

GSP-1

Good probe when sensitivity is needed.  Good for uR detection.  Gamma only.  Good energy response from 50 keV to 2 MeV. 

·         1" X 1" crystal

·         Durable housing

·         Great for General Gamma Detection

·         Works with all Johnson meters

GSP-1 Spec Sheet

GSP-2  2 X 2 Sodium Iodide ScintillatorGSP-2

Good probe when extreme sensitivity is needed.  Excellent for environmental surveys.  Good for uR detection.  Gamma only.  Good energy response from 50 keV to 2 MeV. 

·         2" X 2" crystal for extreme sensitivity

·         Durable housing

·         Great for Environmental Surveys

·         Works with all Johnson meters

GSP-2 Spec Sheet

ASP-2A  2 X 2 Sodium Iodide Scintillator

Zinc Sulphide detector for Alpha only.  Very sensitive alpha contamination detection. Excellent response to Americium, Thorium & Plutonium. 

·         Zinc Sulphide Alpha Detector

·         Durable housing

·         Detects Alphas only

·         Works with all Johnson meters

ASP-2A Spec Sheet

Return to WB Johnson Instruments page